AWG 64 MB MEMORY CARD FOR WII Manuál Strana 48

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 110
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 47
8.10.7 Sine Encoder without data channel (X1)
An sine-cosine encoder without data channel can be used as standard motor feedback.
Select feedback type 7 "SinCos 5V with W&S". Drive executes wake&shake to calculate
the necessary start-up information for the position controller every time the 24V auxiliary
voltage is switched on.
The thermostat contact in the motor is connected via the encoder cable to X1 and evalua
-
ted there.
If lead lengths of more than 50m are planned, please consult our customer service.
Frequency limit: 350 kHz
Don't use this feedback type with vertical load (hanging load).
48 SERVOSTAR
®
300 Product Manual
Electrical installation 09/2006 Kollmorgen
SERVOSTAR 300
Zobrazit stránku 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 109 110

Komentáře k této Příručce

Žádné komentáře