6 Device PowerSupply General Purpose Power Supply (GPDPS)
146 System Reference, January 2001
load capacitance
Basically, each performance range requires a minimum
load capacitance to ensure stable operation. Further
increasing the load capacitance increases the low pass
filter effect and smooths the supply voltage from large
voltage ripples if load conditions change. Alternatively,
high load capacitances slow down dynamic perfor-
mance and introduce current noise into GPDPS
current measurements. This is especially undesirable
in low current measurements (standby or iddq
currents).
The following parameters are of importance from an appli-
cation point of view:
maximum current swing
A high current swing can occur during operation, if the
DUT switches from the standard operational state to
the quiescent state or vice versa. This is typically the
current swing to be considered when selecting the
performance range.
stability of supply voltage range
To guarantee an optimal supply for the DUT, the supply
voltage must be stable within a certain voltage range.
Minimum and maximum supply voltages are specified
in the DUT’s specification sheet. As a rule of thumb, to
guarantee supply voltage stability, the load capacitance
needs to be increased to decrease voltage ripple.
measurement accuracy for low current measurements
(iddq, standby)
Any load capacitance introduces current noise in a
current measurement. The impact on the measurement
accuracy can be significant for very low current
measurements. In general, to take full advantage of the
high GPDPS current measurement accuracy, the load
capacitance should not be larger than 1µF.