High Current Power Supply (HCDPS) 6 Device PowerSupply
System Reference, January 2001
177
HCDPS Switching Voltages (Vbump)
This is described in “Switching DPS Voltages (Vbump)” on
page 155.
Note, however, that the HCDPS board only contains one
supply (channel) and not four as is the case with the
General Purpose and High Voltage Power Supplies.
Ganging HCDPS Boards
Normally a maximum of two boards can be ganged
together to generate up to 200A. The basic procedure for
doing this is described in the section covering the General
Purpose Power Supply (GPDPS) on page 159. However,
you must consider:
• The High Current DPS contains only one channel per
board and not four, in contrast to the General Purpose
and High Voltage DPS.
• Normally, a maximum of only two HCDPS boards
(=channels) can be ganged together
Note that it is not possible to gang different types of power
supplies together.
Disconnecting the HCDPS
This is the same as described on page 162 except that an
HCDPS disconnected in the low impedance mode, forces a
small positive voltage (mV) not 0V as with the GPDPS.
Routing HCDPS Lines
The principles described in the section “Routing DPS
Lines” on page 163 apply to the HCDPS also.